OUTPUT | OUTPUT NUMBER | CH1 | CH2 |
DC VOLTAGE | 13.8V | 13.8V |
RATED CURRENT | 3A | 0.8A |
CURRENT RANGE | 0~3.8A | —- |
RATED POWER | 50W |
RIPPLE & NOISE (max.) | 120mVp-p | —- |
VOLTAGE ADJ. RANGE | CH1:12.5~14.2V |
VOLTAGE TOLERANCE | ±1.0% | —- |
LINE REGULATION | ±0.5% | —- |
LOAD REGULATION | ±0.5% | —- |
SETUP, RISE TIME Note. | 2000ms, 30ms/230VAC 3000ms, 30ms/115VAC at full load |
HOLD UP TIME (Typ.) | 40ms/230VAC 40ms/115VAC at full load |
INPUT | VOLTAGE RANGE | 100 ~ 240VAC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | 0.5 |
EFFICIENCY (Typ.) | 83% |
AC CURRENT (Typ.) | 1A/115VAC 0.5A/230VAC |
INRUSH CURRENT (Typ.) | COLD START 35A/115VAC 70A/230VAC |
LEAKAGE CURRENT | <1mA / 240VAC |
PROTECTION | OVERLOAD | 105 ~ 150% rated output power |
| Protection type : Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE | CH1:15 ~ 18V |
| Protection type : Shut down o/p voltage, re-power on to recover |
BATTERY CUT OFF | 10±1V |
ENVIRONMENT | WORKING TEMP. | -20 ~ +60℃(Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85℃, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/℃(0~45℃) on CH1 output |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A |
OTHERS | MTBF | 257K hrs min. MIL-HDBK-217F (25℃) |
DIMENSION | Enclosed type:110*77*36mm (L*W*H) |